TiMOTION is leading the way in technologies that make automation easier, smoother and more efficient. With our fully customized electric linear actuators, we are able to meet specific design requirements for countless manufacturing industries. We specialize in linear actuation systems that make life easier for consumers and industry alike. See our full product listing below, and read more about how TiMOTION products are revolutionizing how manufacturers create high-quality end products.

JP4 Series

i1.jpg

Features :

  • Voltage of motor: 12, 24V DC; 12, 24V DC (PTC)

  • Maximum load: 4,500N in push

  • Maximum load: 3,000N in pull

  • Maximum speed at full load: 24mm/s (with 500N in a push or pull condition)

  • Stroke: ≥20~1000mm

  • Minimum installation dimension: Stroke+289mm

  • IP rating: Up to IP69K

  • Color: Black or grey

  • Certificate: UL73

  • Operational temperature range: -5°C~+65°C

  • Operational temperature range at full performance: +5°C~+45°C

  • Storage temperature range: -40°C~+70°C

  • An inline actuator designed for small spaces

​

TA1 Series

i4.jpg

Features :

  • Voltage of motor: 12, 24, 36V DC or 24V DC (PTC)

  • Maximum load: 10,000N in push

  • Maximum load: 4,000N in pull

  • Maximum speed at full load: 23.4mm/s (with 1,000N in a push or pull condition)

  • Stroke: 25~1000mm

  • Minimum installation dimension: ≥ Stroke+163mm

  • Color: Black or grey

  • IP rating: Up to IP66W

  • Certificate: IEC60601-1, ES60601-1, EN60601-1-2, EMC

  • Operational temperature range: +5°C~+45°C

  • Options: Safety nut, quick release, Hall sensors

​

TA6 Series

i7.jpg

Features :

  • Voltage of motor: 12, 24, 36V DC or 24V DC (PTC)

  • Maximum load: 10,000N in push

  • Maximum load: 4,000N in pull

  • Maximum speed at full load: 23.4mm/s (with 1,000N in a push or pull condition)

  • Stroke: 25~1000mm

  • Minimum installation dimension: ≥ Stroke+163mm

  • Color: Black or grey

  • IP rating: Up to IP66W

  • Certificate: IEC60601-1, ES60601-1, EN60601-1-2, EMC

  • Operational temperature range: +5°C~+45°C

  • Options: Safety nut, quick release, Hall sensors

​

TA14 Series

i10.jpg

Features :

  • Voltage of motor: 12, 24, 36V DC or 24V DC (PTC)

  • Maximum load: 6,000N in push

  • Maximum load: 4,000N in pull

  • Maximum speed at full load: 23.4mm/s (with 1,000N in a push or pull condition)

  • Stroke: 25~1000mm

  • Minimum installation dimension: ≥ Stroke+163mm

  • Color: Black or dark grey

  • Certificate: UL962, EMC

  • Operational temperature range at full performance: +5°C~+45°C

  • For direct-cut system: Can function without control box

​

TA26 Series

i1.jpg

Features :

  • Voltage of motor: 12, 24, 36V DC or 24V DC (PTC)

  • Maximum load: 6,000N in push

  • Maximum load: 4,000N in pull

  • Maximum speed at full load: 23.4mm/s (with 1,000N in a push or pull condition)

  • Stroke: 25~1000mm

  • Minimum installation dimension: ≥ Stroke+163mm

  • Color: Black or dark grey

  • Certificate: UL962, EMC

  • Operational temperature range at full performance: +5°C~+45°C

  • For direct-cut system: Can function without control box

​

TA37 Series

i1.jpg

Features :

  • Voltage of motor: 12, 24, 36V DC or 24V DC (PTC)

  • Maximum load: 6,000N in push

  • Maximum load: 4,000N in pull

  • Maximum speed at full load: 23.4mm/s (with 1,000N in a push or pull condition)

  • Stroke: 25~1000mm

  • Minimum installation dimension: ≥ Stroke+163mm

  • Color: Black or dark grey

  • Certificate: UL962, EMC

​

MA1 Series

i2.jpg

Features :

  • Spindle: ACME or Ball screw

  • Voltage of motor: 12V DC, 24V DC, 36V DC, 110V AC, or 220V AC

  • Maximum load: 4,500N in pull/push

  • Maximum speed at full load: 48mm/s (Ball screw, DC motor, with 2,500N)

  • Stroke: 20~1000mm (ACME screw); 50~800mm (Ball screw)

  • Minimum installation dimension: ≥Stroke+160mm (without POT)

  • Color: Black

  • IP rating: IP69K

  • Operational temperature range: -30°C~+65°C

  • Operational temperature range at full performance: +5°C~+45°C

  • Options: Overload clutch, Hall sensor(s), POT, manual crank function

  • Mechanical or electromagnetic brake

  • Higher duty cycle (25%), corrosion proof

​

TA2 Series

i5.jpg

Features :

  • Voltage of motor: 12, 24, 36, 48V DC, or 12, 24, 36, 48V DC (PTC)

  • Maximum load: 1,000N in pull and push

  • Maximum speed at full load: 51mm/s (with 120N in a push or pull condition)

  • Stroke: 20~1000mm

  • Minimum installation dimension: Stroke+105mm (without output signals)

  • Color: Silver

  • Certificate: IEC60601-1

​

TA7 Series

i7.jpg

Features :

  • Voltage of motor: 12, 24, 36, 48V DC

  • Maximum load: 3,500N in push and pull

  • Maximum speed at full load: 13.5mm/s (with 1,500N in a push or pull condition)

  • Standard stroke: 20~600mm

  • Minimum installation dimension: ≥ Stroke+112mm

  • Color: Silver

  • IP rating: Up to IP66

  • Option: POT, Hall sensor(s)

  • Certificate: IEC60601-1, ES60601-1, IEC60601-1-2, UL962, EMC

  • Operational temperature range: +5°C~+45°C

  • With very low noise, small size for easy installation

  • Suitable for patient hoist application

​

TA16 Series

i1.jpg

Features :

  • Voltage of motor: 12, 24, 36, 48V DC

  • Maximum load: 3,500N in push and pull

  • Maximum speed at full load: 13.5mm/s (with 1,500N in a push or pull condition)

  • Standard stroke: 20~600mm

  • Minimum installation dimension: ≥ Stroke+112mm

  • Color: Silver

  • IP rating: Up to IP66

  • Option: POT, Hall sensor(s)

  • Certificate: IEC60601-1, ES60601-1, IEC60601-1-2, UL962, EMC

  • Operational temperature range: +5°C~+45°C

  • With very low noise, small size for easy installation

  • Suitable for patient hoist application

​

TA31 Series

i1.jpg

Features :

  • Voltage of motor: 12, 24, 36, 48V DC

  • Maximum load: 3,500N in push and pull

  • Maximum speed at full load: 13.5mm/s (with 1,500N in a push or pull condition)

  • Standard stroke: 20~600mm

  • Minimum installation dimension: ≥ Stroke+112mm

  • Color: Silver

  • IP rating: Up to IP66

  • Option: POT, Hall sensor(s)

  • Certificate: IEC60601-1, ES60601-1, IEC60601-1-2, UL962, EMC

  • Operational temperature range: +5°C~+45°C

  • With very low noise, small size for easy installation

  • Suitable for patient hoist application

​

MA2 Series

i3.jpg

Features :

  • Voltage of motor: 12V DC, 24V DC, 36V DC; 12V DC, 24V DC, 36V DC (thermal control)

  • Maximum load: 6,000N in push and pull

  • Maximum speed at full load: 43mm/s (with 1000N in a push or pull condition)

  • Stroke: ≥ 25~1000mm

  • Minimum installation dimension: Stroke+131mm

  • IP rating: Up to IP69K

​

TA5L Series

i6.jpg

Features :

  • Voltage of motor: 24V DC

  • Maximum load: 1,200N in push

  • Maximum speed at full load: 20.8mm/s (with 1200N in a push or pull condition)

  • Stroke: 332mm

  • Retracted length: 157mm

  • Color: Black

  • Noise level: Under 48 dB(A)

  • Certificate: Noise level test (SGS), UL962, EMC

TA9 Series

i8.jpg

Features :

  • Voltage of motor: 12, 24V DC or 24V DC (PTC)

  • Maximum load: 2,500N in push

  • Maximum load: 1,000N in pull

  • Maximum speed at full load: 30mm/s (with 500N in a push or pull condition)

  • Stroke: ≥ 20 ~ 600mm

  • Minimum installation dimension: ≥ Stroke+140mm

  • Color: Black or grey

  • IP rating: Up to IP66

  • Certificate: IEC60601-1, ES60601-1, IEC60601-1-2, UL962, EMC

  • Operational temperature range: +5°C~+45°C

  • Option: Hall sensors

​

TA23 Series

i1.jpg

Features :

  • Voltage of motor: 12, 24, 36V DC or 24V DC (PTC)

  • Maximum load: 10,000N in push

  • Maximum load: 4,000N in pull

  • Maximum speed at full load: 23.4mm/s (with 1,000N in a push or pull condition)

  • Stroke: 25~1000mm

  • Minimum installation dimension: ≥ Stroke+163mm

  • IP rating: Up to IP66W

  • Certificate: IEC60601-1, ES60601-1, IEC60601-1-2, EMC

  • Options: Hall sensors, manual release (for patient hoist)

  • Suitable for patient hoist application

​

TA36 Serie

i1.jpg

Features :

  • Voltage of motor: 12, 24, 36V DC or 24V DC (PTC)

  • Maximum load: 10,000N in push

  • Maximum load: 4,000N in pull

  • Maximum speed at full load: 23.4mm/s (with 1,000N in a push or pull condition)

  • Stroke: 25~1000mm

  • Minimum installation dimension: ≥ Stroke+163mm

  • IP rating: Up to IP66W

  • Certificate: IEC60601-1, ES60601-1, IEC60601-1-2, EMC

  • Options: Hall sensors, manual release (for patient hoist)

  • Suitable for patient hoist application

​

bottom of page